A00068.gifBolted joint (Topic: 12046)

Calculate the capacity of the bolted joint:

A00121.gif

R 2 Flat bars. Alloy EN AW-6082-T6.

R p0,2 = 260 MPa

Rm = 310 MPa

Bolt: M10 stainless steel, A4.

R p0,2 = 600 MPa

Rm = 800 MPa

R 5.1.1.1 Design strength per bolt in shear:

A00122.gif

R 5.1.1.2 Design strength in bearing for each bolt:

A00123.gif

TAB 5.3 Edge distance. Reduced deformations = 2d

A00124.gif

References: [16]